PFAS groundwater purification plant, Berlin-Tegel
Hydraulic barrier for PFAS-contaminated groundwater
Location
Berlin-Tegel
Client
Berlin waterworks
Parameters
Flow rate 125 - 150 m³/h water
Performance period
since November 2022
Treatment plant for groundwater with PFAS-pollution
Relevant concentrations of the pollutant group PFAS were detected in the catchment area of the Tegel waterworks. The groundwater from the contaminated wells is routed to a purification plant where it is cleaned of PFAS after pre-treatment to remove impurities.
Pollutants
- Σ PFAS max. approx. 1,240 ng/L
- PFOS: approx. 700 ng/L, PFOA: approx. 40 ng/L, PFHxS: approx. 500 ng/L
- Iron / manganese: approx. 1.4 mg/L / approx. 0.4 mg/L
- DOC: approx. 4 mg/L
- Purification performance: 1 ng/L single substance PFOS, PFOA, PFNA and PFHxA
Scope of services
- Gravel filter / deferrization
- Water activated carbon filter, two-stage (Vges= 2 x 75 m³)
- Activated carbon type PFAS optima®